Hyperthermia Therapy System – IP 1, 433.92 MHz

IP 1

Deep hyperthermia unit that focuses energy on a defined target area at a depth of 1 to 8 cm, raising it to a controlled 40–45 °C without disturbing surrounding tissue. 433.92 MHz RF generator, touchscreen with a smart mode to set target depth, temperature and power, and real-time power monitoring.

Targeted deep heating, 1–8 cm, to 40–45 °C

433.92 MHz RF; touchscreen smart mode

Overview

Hyperthermia Therapy System

Hyperthermia focuses energy on a well-defined area inside the body, at a variable depth from 1 cm up to 8 cm, bringing the target volume to a high, controlled temperature of 40–45 °C without appreciable effect on the adjacent tissue.

What makes it a distinct form of thermotherapy is the excellent reproducibility of the thermal parameters, achieved through sophisticated control systems and targeted energy delivery. This induction heating method suits conditions that have been difficult to resolve and have become chronic, such as contractures, tendonitis, muscle injuries and arthritis.

The touchscreen panel has a smart mode with three parameters: target depth, temperature and power. Forward and reflected power are measured continuously in real time.

Why buy from Physiomed

Key Features

Built for clinical performance

✓
Targeted heating of a defined volume at 1–8 cm depth
✓
Controlled target temperature of 40–45 °C
✓
Reproducible thermal parameters
✓
Touchscreen panel
✓
Smart mode: set target depth, temperature and power
✓
Telton microstrip technology
✓
Silicone bag with thermo-regulated liquid for patient coupling
✓
Forward and reflected power measured continuously in real time
✓
Mismatch protection: total (infinite ROS)
✓
Safety controls: absorbed current sensing and operating temperature

Technical Specifications

Specifications

Model number IP 1
Technology Telton microstrip
Patient coupling Silicone bag with thermo-regulated liquid
Rated frequency 433.92 MHz
Maximum working power 200 W
RF generator maximum power output 100 W
Power setting 0–100% in 5% steps
Transfer efficiency 90% minimum (RF to useful heat)
Maximum therapeutic penetration 80 mm
Maximum footprint 186 × 196 mm
Actual field (50% SAR) 80 × 120 mm

Clinical Protocols

Indications

Recommended starting parameters by indication. Final protocols should be set by the treating clinician.

Contractures
Muscle contractures.
Tendonitis
Tendon inflammation.
Muscle injuries
Muscular injuries.
Arthritis
Arthritic joint conditions.

Related Products

You may also consider

VOGUE 7.0 TECAR

Fisiowarm

Fisiowarm 7.0 — the ultimate tecar therapy experience
Uniq electrode: capacitive + resistive in one, up to 400 W
YOUTECARX

YoutecarX

Fully customisable tecar platform
Capacitive + resistive, unipolar / bipolar / NeutroDinamico
Fisiowarm Tecar Ther...

Fisiowarm

Low-voltage tecar: under 200 V, heat generated in the tissue
Vogue 400 W, Pure 300 W, Easy 200 W; tablet app control

Interested in the Hyperthermia Therapy System – IP 1, 433.92 MHz?

Request a demo, pricing or clinical consultation. Our team responds within one business day.