Shinhwa Medical spinal decompression and mobilization system: short treatment, high success rate, fully customized. Feedback-driven cervical and lumbar decompression, Cox flexion-distraction, Cyriax rotation, unilateral correction and thoracic/lumbar mobilization in one platform. GMP, CE 0068, ISO 13485.
Overview
Spine-MT CORE is a spinal decompression and mobilization system built around a simple promise: short treatment, high success rate, fully customized to the patient. It combines targeted cervical and lumbar decompression with mobilization and correction therapies in a single integrated platform, engineered to Shinhwa Medical’s global standard for spinal therapy.
Together these let the same platform move from precise segmental decompression to broader mobilization and exercise, all governed by the same feedback and program logic.
Key Features
Technical Specifications
| Treatment mode | Principle | Adjustable range |
| Cervical target angle | Flexion-distraction (Cox technique) | 0° to 25° |
| Lumbar target angle | Flexion-distraction (Cox technique) | 0° to +25° |
| Cervical unilateral application | Treats according to the herniated direction of the disc | 0° to 20° |
| Lumbar unilateral application | Treats according to the herniated direction of the disc | 0° to 20° |
| Lumbar rotation application | Cyriax technique; adjusts rotation range by type of disc escape | Stop position 0° to 18° |
| Cervical decompression | Feedback system, exercise, decompression and automatic program | — |
| Lumbar decompression | Feedback system, exercise, decompression and automatic program | — |
| Thoracic & lumbar mobilization | Bilateral left/right upper-body mobilization | 3 intensity levels, 5 angle steps |
| Manufacturer | Shinhwa Medical |
| Program modes | Manual Mode, Special Mode (automatic) |
| Certification | GMP, CE (0068), ISO 13485:2016 |
| Indication | Approach |
| Herniated nucleus pulposus | Feedback-driven decompression creates space for the disc to move and applies a centripetal force that helps draw herniated material back in. |
| Degenerative disc disease | Decompression and mobilization together relieve disc pressure and support the surrounding joints and muscles. |
| Scoliosis | Unilateral correction and rotation address the asymmetric spinal and muscular imbalance underlying the curve. |
| Joint problems | Mobilization intensity and angle settings gently restore range of motion in affected spinal joints. |
| Muscle imbalance | Real-time left/right muscle tension monitoring lets treatment be adjusted mid-session. |
Final protocols are set by the treating clinician.
| SPINE-MT CORE | Spine MT Core spinal decompression and mobilization system (Shinhwa Medical) |
Clinical Protocols
Recommended starting parameters by indication. Final protocols should be set by the treating clinician.
Related Products
Request a demo, pricing or clinical consultation. Our team responds within one business day.