AXELERO Gait & Balance Treadmill with ELEVEO

Meden-Inmed

Meden-Inmed AXELERO gait and balance treadmill with a built-in posturographic plate for real-time Center of Pressure tracking, a 43″ biofeedback display, adjustable handrails for children and adults, standardized tests (6MWT, LoS, Romberg) and optional ELEVEO dynamic unloading of up to 160 kg.

Gait and balance treadmill with real-time CoP biofeedback

Optional ELEVEO body-weight support up to 160 kg

Overview

Gait & Balance Training Treadmill

AXELERO Gait & Balance is Meden-Inmed’s most advanced treadmill, built not only for motor rehabilitation and biofeedback-guided training but for objective, quantified measurement of a patient’s gait and running parameters. It is designed for training gait-pattern disturbances and balance, so the same session both treats and measures.

At its core is a posturographic plate beneath the treadmill belt that locates the patient’s Center of Pressure (CoP) in real time and detects automatically whether the patient is on the device. Together with a large 43-inch real-time biofeedback display, adjustable integrated handrails and a full software suite for data tracking and analysis, AXELERO turns everyday gait training into a measurable, repeatable clinical process.

For patients with significant gait dysfunction, the optional ELEVEO dynamic unloading system mounts above the treadmill and relieves up to 160 kg of body weight, so training can start before full weight-bearing is possible.

Why buy from Physiomed

Key Features

Built for clinical performance

✓
Built-in posturographic plate with real-time Center of Pressure (CoP) tracking
✓
43-inch real-time biofeedback display
✓
Gait symmetry analysis: stride length, weight distribution, stance and swing time
✓
Standardized tests: 6-Minute Walk, Limits of Stability and Romberg
✓
Optional ELEVEO dynamic unloading, up to 160 kg body-weight support
✓
Wireless tablet control, session logging and remote emergency stop

Technical Specifications

Specifications

Manufacturer Meden-Inmed
Measurement Posturographic plate under the belt: CoP (X/Y), belt pressure, automatic patient detection
Display 43-inch real-time biofeedback screen
Handrail width 43–69 cm
Handrail height 66–94.5 cm
Tracked parameters Cadence, speed, step count, distance (left and right), stance phase, belt speed
Standardized tests 6MWT, Limits of Stability (LoS), Romberg’s test
Body-weight support Optional ELEVEO dynamic unloading, up to 160 kg
Control Wireless tablet (therapist), patient remote with emergency STOP
Safety Security key, emergency stop button, “no user on treadmill” detection
Dimensions 256 × 78 × 195 cm
Weight 200 kg
Classification Class I, type B
Optional ELEVEO Dynamic Unloading
  • Mounts above the treadmill
  • Relieves up to 160 kg of body weight during training
Biofeedback & Assessment
  • “Butterfly” chart of CoP movement over time
  • Real-time bar charts of spatial and temporal gait symmetry
  • Left vs. right: average and maximum load, stance and swing time
  • 6-Minute Walk Test, Limits of Stability test, Romberg’s test (30 s eyes open / closed)
  • All sessions logged to the patient account and comparable with any past session
Clinical Approach by Condition
Condition Approach
Stroke Real-time biofeedback and adjustable handrail support help retrain gait symmetry and weight-bearing as motor control returns.
Cerebral disorders CoP tracking and symmetry analysis support structured retraining of balance and coordination.
Spinal cord injuries Belt speed control and optional ELEVEO weight support allow safe, progressive gait training with significant lower-limb impairment.
Parkinson’s disease Visual biofeedback on stride length and cadence helps address the shortened, shuffling Parkinsonian gait.
Cerebral palsy Handrail width and height adjust for children and adults, supporting long-term motor skill development.

Set handrail width and height to the patient before training and adjust as confidence improves.

Ordering Details
AXELERO AXELERO Gait & Balance treadmill
ELEVEO ELEVEO dynamic unloading system (optional)

Clinical Protocols

Indications

Recommended starting parameters by indication. Final protocols should be set by the treating clinician.

Neurological gait disorders
Stroke, Parkinson’s disease and cerebral disorders, using real-time biofeedback on symmetry, stride and cadence.
Spinal cord injury & cerebral palsy
Progressive gait training with speed control, adjustable handrails and optional ELEVEO weight support.
Balance & objective assessment
CoP-guided balance retraining and standardized 6MWT, LoS and Romberg testing for outcome tracking.
Motor rehabilitation
supporting recovery of walking function following neurological or orthopedic injury