UPPER LIMBS FEEDBACK SYSTEM

Functional rehabilation

Description

Patients suffer from Upper Limbs Hemiplegia and Dysfunction who need upper limbs rehabilitation caused by nervous system diseases, cerebrovascular disease, Serious Traumatic Brain injury etc. Such as Stroke, Parkinson, Cerebral thrombosis etc.

FEATURES
Display interface: Magnificent computer virtual operation interface with 32 inches LED TV.
Sensor technology: Adopts non touch angle sensor and pressure sensor.

Training mode: single left and right hand training. Left and right forearms are equipped.
Software recognition function: left and right hands can be recognized intelligently.
Evaluation function: Evaluate patient’s joints motion range and grip force. The evaluation results are showed by 3D and plane graph. Evaluation reports are created which can be used for evaluating patient’s rehabilitation status for the therapist. Shoulder joint adduction and extortion evaluation ranges: 0~150 °, Shoulder joint antler flexion evaluation ranges: 0~80 °, Elbow joint flexion evaluation ranges: 0~135 °. Distal radio ulnar joint phonation and sup nation evaluation ranges: 0~180. Grip force evaluation ranges: 0~10 Patient data base: Records patient’s basic information, evaluation Result and all the training data. Evaluation result and training data can be exchanged to EXCEL files which are convenient to print. Patient information contains name, gender, and age and myo dynamic degree. Training data contains training arm, time, date, difficulty, grip force and scores.. Visual and audio feedback provide real time virtual training scene, training voice prompt and scene sound effect.
Training modes: 1D, 2D, 3D 20 training games .
Software update: Software interface and games numbers update. Hand Training.

MODEL No: NX-4 – Upper Limbs Feedback system
MODEL No: NX-4 ADV – Advanced Upper Limbs Feedback System

Additional information

MODEL No:

NX-4
NX- 4 ADV

Voltage:

AC220V/50Hz

Power:

130VA

Upper arm length:

22cm~31 cm

Lower arm length:

24~40 cm

Arm height:

98~138 cm

Arm horizontal adjusting length:

0~80 cm

Upper arm gravity compensation:

0~10 Kg

Lower arm gravity compensation:

0~5 Kg

Number of joints mechanical locking device:

4

Sampling frequency of joint motion range:

128 Hz

Angle sensor sensitivity:

2 mv/N